4K Cryocoolers
First introduced in 1995, the RDK-Series 4K Gifford-McMahon Cryocoolers are the most reliable and versatile systems available in the marketplace.
SHI’s 4K Gifford-McMahon Cryocoolers are recognized as the most reliable and versatile systems available in the marketplace. They feature high cooling capacities, compact designs and are orientation-free. Models like the RDK-408D2 are the standard for MRI and other superconducting magnets. These 4K Cryocoolers can be found cooling a wide variety of analytical and experimental devices, and offer a very cost effective alternative to open-cycle liquid helium systems.
RDK-101D 4K Cryocooler Series
Standard scope of Supply
- RDK-101D Cold Head
- HC-4E2, CNA-11B/C or Zephyr® Compressor
- 3 m (10 ft.) Helium Gas Lines
- 6 m (20 ft.) Cold Head Cable
- Tool Kit
Specifications
Specifications
Power Supply |
50 Hz |
60 Hz |
2nd Stage Capacity1 |
0.1 W @ 4.2 K |
1st Stage Capacity1 |
3.0 W @ 60 K |
5.0 W @ 60 K |
Minimum Temperature2 |
< 3.0 K |
Cooldown Time to 4.2 K2 |
150 Minutes |
Weight |
7.2 kg (15.9 lbs.)3 |
Maintenance |
10,000 Hours |
- 1.With HC-4E2 and Zephyr compressors, 2nd stage capacity is 0.16/0.2 W @ 4.2 K (50/60 Hz). 1st stage capacity is 3.0/5.0 W @ 45 K (50/60 Hz).
- 2.Lowest temperature and cooldown time are for reference only. (Dependent upon ambient temperature, cooling water temperature, etc.)
- 3.Cold Head only. Drive unit weighs 1.0 kg (2.2 lbs.)
Specifications subject to change without notice.
RDK-305D 4K Cryocooler Series
Standard scope of Supply
- RDK-305D Cold Head
- FA-40L/H Compressor
- 10 m (33 ft.) Helium Gas Lines
- 10 m (33 ft.) Cold Head Cable
- Tool Kit
Specifications
Specifications
Power Supply |
50 Hz |
60 Hz |
2nd Stage Capacity |
0.4 W @ 4.2 K |
1st Stage Capacity |
15 W @ 40 K |
20 W @ 40 K |
Minimum Temperature1 |
< 3.5 K |
Cooldown Time to 4.2 K1 |
120 Minutes |
Weight |
16.0 kg (35.3 lbs.) |
Maintenance |
10,000 Hours |
- 1.Lowest temperature and cooldown time are for reference only. (Dependent upon ambient temperature, cooling water temperature, etc.)
Specifications subject to change without notice.
RDK-205D 4K Cryocooler Series
Standard scope of Supply
- RDK-205D Cold Head
- CKW-21A Compressor
- 10 m (33 ft.) Helium Gas Lines
- 10 m (33 ft.) Cold Head Cable
- Tool Kit
Specifications
Specifications
Power Supply |
50 Hz |
60 Hz |
2nd Stage Capacity |
0.5 W @ 4.2 K |
1st Stage Capacity |
3.0 W @ 50 K |
4.0 W @ 50 K |
Minimum Temperature1 |
< 3.5 K |
Cooldown Time to 4.2 K1 |
90 Minutes |
Weight |
14.0 kg (30.9 lbs.) |
Maintenance |
10,000 Hours |
- 1.Lowest temperature and cooldown time are for reference only. (Dependent upon ambient temperature, cooling water temperature, etc.)
Specifications subject to change without notice.
RDK-408D2 4K Cryocooler Series
Standard scope of Supply
- RDK-408D2 Cold Head
- CSA-71A, F-50L/H, F-70L/H, CNA-61C/D or FA-70L/H Compressor
- 6 m (20 ft.) Helium Gas Lines [10 m (33 ft.) with CNA-61C/D Compressor]
- 6 m (20 ft.) Cold Head Cable [10 m (33 ft.) with CNA-61C/D Compressor]
- Tool Kit
Specifications
Specifications
Power Supply |
50 Hz |
60 Hz |
2nd Stage Capacity |
1.0 W @ 4.2 K |
1st Stage Capacity |
40 W @ 43 K |
50 W @ 43 K |
Minimum Temperature1 |
< 3.5 K |
Cooldown Time to 4.2 K1 |
60 Minutes |
Weight |
18.0 kg (39.7 lbs.) |
Maintenance |
10,000 Hours |
- 1.Lowest temperature and cooldown time are for reference only. (Dependent upon ambient temperature, cooling water temperature, etc.)
Specifications subject to change without notice.
RDK-412D4 4K Cryocooler Series
Standard scope of Supply
- RDK-412D4 Cold Head
- F-40L/H, F-50L/H, FA-40L/H or CSA-71A Compressor
- 20 m (66 ft.) Helium Gas Lines
- 6-20 m (20-66 ft.) Cold Head Cable
- Tool Kit
Specifications
Specifications
Power Supply |
50 Hz |
60 Hz |
2nd Stage Capacity1 |
1.25 W @ 4.2 K |
1st Stage Capacity1 |
53 W @ 43 K |
60 W @ 43 K |
Minimum Temperature2 |
< 3.5 K |
Cooldown Time to 4.2 K2 |
60 Minutes |
Weight |
20 kg (44.1 lbs.) |
Maintenance |
10,000 Hours |
- 1.With F-40 and FA-40 compressors, 2nd stage capacity is 1.0 W @ 4.2 K (50/60 Hz). 1st stage capacity is 42/48 W @ 43 K (50/60 Hz).
- 2.Lowest temperature and cooldown time are for reference only. (Dependent upon ambient temperature, cooling water temperature, etc.)
Specifications subject to change without notice.
RDK-415D 4K Cryocooler Series
Standard scope of Supply
- RDK-415D Cold Head
- CSA-71A, F-50L/H, F-70L/H, CNA-61C/D or FA-70L/H Compressor
- 20 m (66 ft.) Helium Gas Lines or 6 m (20 ft.) Helium Gas Lines with Buffer Tank [10 m (33 ft.) with CNA-61C/D Compressor]
- 6 m (20 ft.) Cold Head Cable [10 m (33 ft.) with CNA-61C/D Compressor]
- Tool Kit
Specifications
Specifications
Power Supply |
50 Hz |
60 Hz |
2nd Stage Capacity |
1.5 W @ 4.2 K |
1st Stage Capacity |
35 W @ 50 K |
45 W @ 50 K |
Minimum Temperature1 |
< 3.5 K |
Cooldown Time to 4.2 K1 |
60 Minutes |
Weight |
18.5 kg (40.8 lbs.) |
Maintenance |
10,000 Hours |
- 1.Lowest temperature and cooldown time are for reference only. (Dependent upon ambient temperature, cooling water temperature, etc.)