Water-Cooled Compressors
SHI’s Closed-loop Helium Compressors deliver high pressure, oil-free helium to both small and large-scale applications.
All SHI Cryocoolers, Pulse Tubes and Cryopumps are driven by highly-efficient and reliable helium compressors. These compressors boast industry-leading 20,000 or 30,000 hour maintenance intervals, and are available in single-phase and three-phase, low and high voltage, and water and air-cooled versions.
CSW-61 Indoor Water-Cooled Compressor Series
Specifications
Specifications
|
CSW-61C |
CSW-61D |
Electrical Supply |
3 Phase 200-230 V, 50/60 Hz |
3 Phase 378-528 V, 50/60 Hz |
Power Consumption1 |
0.9 kW/pump (KZ-8L) 1.5 kW/pump (KZ-12L) |
Ambient Temperature2 |
5-35 ºC (41-95 °F) |
Cooling water (Inlet) |
4-10 L/min. (1.1-2.6 gal./min.) 4-28 °C (40-82 °F) |
Dimensions (HxWxD) |
865 x 455 x 660 mm (34.1 x 17.9 x 26.0 in.) |
865 x 455 x 640 mm (34.1 x 17.9 x 25.2 in.) |
Weight |
130 kg (287 lbs.) |
Maintenance |
30,000 Hours |
- 1.Typical power consumption
- 2.Cooling capacity may degrade if ambient temperature is above 28 °C (82 °F).
Specifications subject to change without notice.
HC-4E Indoor Water-Cooled Compressor Series
Specifications
Specifications
Electrical Supply1 |
1 Phase 200 V, 230/240 V, 50 Hz 208/230 V, 60 Hz |
Power Consumption2 |
2.6 kW at 50 Hz 3.0 kW at 60 Hz |
Ambient Temperature3 |
4-40 ºC (40-104 °F) |
Cooling water (Inlet) |
2.7 L/min. (0.7 gal./min.) 4-27 °C (40-80 °F) |
Dimensions (HxWxD) |
504 x 430 x 485 mm (19.8 x 16.9 x 19.1 in.) |
Weight |
75 kg (165 lbs.) 85 kg (180 lbs.) w/transformer |
Maintenance |
30,000 Hours |
- 1.Power may differ depending upon the cold head used.
- 2.Typical power consumption
- 3.Cooling capacity may degrade if ambient temperature is above 28 °C (82 °F).
Specifications subject to change without notice.
CKW-21A Indoor Water-Cooled Compressor Series
Specifications
Specifications
Electrical Supply1 |
3 Phase 200 V, 50/60 Hz |
Power Consumption2 |
2.7-3.3 kW at 50 Hz 3.5-4.0 kW at 60 Hz |
Ambient Temperature3 |
5-35 ºC (41-95 °F) |
Cooling water (Inlet) |
3.0-3.5 L/min. (0.8-0.9 gal./min.) 28 °C (82 °F) |
Dimensions (HxWxD) |
471 x 401 x 450 mm (18.5 x 15.8 x 17.7 in.) |
Weight |
70 kg (155 lbs.) |
Maintenance |
20,000 Hours |
- 1.Power may differ depending upon the cold head used.
- 2.Typical power consumption
- 3.Cooling capacity may degrade if ambient temperature is above 28 °C (82 °F).
Specifications subject to change without notice.
HC-8E Indoor Water-Cooled Compressor Series
Specifications
Specifications
Electrical Supply1 |
3 Phase 220 V, 50 Hz 220/230 V, 60 Hz |
Power Consumption2 |
3.7 kW at 50 Hz 4.3 kW at 60 Hz |
Ambient Temperature3 |
4-40 ºC (40-104 °F) |
Cooling water (Inlet) |
5.7-9.5 L/min. (1.5-2.5 gal./min.) 4-21 °C (40-70 °F) |
Dimensions (HxWxD) |
504 x 430 x 485 mm (19.8 x 16.9 x 19.1 in.) |
Weight |
75 kg (165 lbs.) |
Maintenance |
30,000 Hours |
- 1.Power may differ depending upon the cold head used.
- 2.Typical power consumption
- 3.Cooling capacity may degrade if ambient temperature is above 28 °C (82 °F).
Specifications subject to change without notice.
F-50 Indoor Water-Cooled Compressor Series
Specifications
Specifications
|
F-50L |
F-50H |
Electrical Supply1 |
3 Phase 200 V, 50/60 Hz |
3 Phase 380, 400, 415 V, 50 Hz 480 V, 60 Hz |
Power Consumption2 |
6.5-7.2 kW at 50 Hz 7.5-8.3 kW at 60 Hz |
Ambient Temperature3 |
5-35 ºC (41-95 °F) |
Cooling water (Inlet) |
7-10 L/min. (1.8-2.6 gal./min.) 28 °C (82 °F) |
Dimensions (HxWxD) |
591 x 450 x 588 mm (23.3 x 17.7 x 23.2 in.) |
Weight |
120 kg (264 lbs.) |
Maintenance |
30,000 Hours |
- 1.Power may differ depending upon the cold head used.
- 2.Typical power consumption
- 3.Cooling capacity may degrade if ambient temperature is above 28 °C (82 °F).
Specifications subject to change without notice.
F-100 Indoor Water-Cooled Compressor Series
Specifications
Specifications
|
F-100L |
F-100H |
Electrical Supply1 |
3 Phase 200 V, 50 Hz 200, 230 V, 60 Hz |
3 Phase 380, 400, 415 V, 50 Hz 460, 480 V, 60 Hz |
Power Consumption2 |
11.8-13.7 kW at 50 Hz 14.5-16.3 kW at 60 Hz |
Ambient Temperature3 |
5-35 ºC (41-95 °F) |
Cooling water (Inlet) |
6-10 L/min. (1.6-2.6 gal./min.) 4-28 °C (39-82 °F) |
Dimensions (HxWxD) |
1331 x 511 x 512 mm (52.4 x 20.1 x 20.2 in.) |
Weight |
250 kg (551 lbs.) |
Maintenance |
30,000 Hours |
- 1.Typical power consumption
- 2.Cooling capacity may degrade if ambient temperature is above 28 °C (82 °F).
Specifications subject to change without notice.
F-70 Indoor Water-Cooled Compressor Series
Specifications
Specifications
|
F-70L |
F-70H |
Electrical Supply1 |
3 Phase 200 V, 50/60 Hz |
3 Phase 380-415 V, 50 Hz 480 V, 60 Hz |
Power Consumption2 |
6.6-6.9 kW at 50 Hz 7.5-7.8 kW at 60 Hz |
Ambient Temperature3 |
4-40 ºC (40-104 °F) |
Cooling water (Inlet) |
6-9 L/min. (1.6-2.4 gal./min.) 5-25 °C (41-77 °F) |
Dimensions (HxWxD) |
532 x 443 x 493 mm (20.9 x 17.4 x 19.4 in.) |
Weight |
100 kg (225 lbs.) |
Maintenance |
30,000 Hours |
- 1.Power may differ depending upon the cold head used.
- 2.Typical power consumption
- 3.Cooling capacity may degrade if ambient temperature is above 28 °C (82 °F).
Specifications subject to change without notice.