Water-Cooled Compressors
	
		SHI’s Closed-loop Helium Compressors deliver high pressure, oil-free helium to both small and large-scale applications.
		All SHI Cryocoolers, Pulse Tubes and Cryopumps are driven by highly-efficient and reliable helium compressors.  These compressors boast industry-leading 20,000 or 30,000 hour maintenance intervals, and are available in single-phase and three-phase, low and high voltage, and water and air-cooled versions.
	
	CNA-11 Indoor Air-Cooled Compressor Series
	
		
		
			Specifications
			
				Specifications
				
					
				
				
					
						|   | 
						CNA-11B | 
						CNA-11C | 
					
					
						| Electrical Supply1 | 
						1 Phase 100 V 50/60 Hz | 
						1 Phase 100, 120, 220, 230, 240 V, 50/60 Hz | 
					
					
						| Power Consumption2 | 
						1.2-1.3 kW at 50 Hz 1.3-1.5 kW at 60 Hz | 
					
					
						| Ambient Temperature3 | 
						4-38 ºC (39-100 °F) | 
					
					
						| Cooling Air | 
						2.7 m3/min. (95 cfm), 50 Hz 3.3 m3/min. (117 cfm), 60 Hz | 
					
					
						| Dimensions (HxWxD) | 
						400 x 390 x 450 mm (15.7 x 15.3 x 17.7 in.) | 
						610 x 390 x 450 mm (24.0 x 15.4 x 17.7 in.) | 
					
					
						| Weight | 
						42 kg (73 lbs.) | 
						75 kg (165 lbs.) | 
					
					
						| Maintenance | 
						30,000 Hours | 
					
				
			
		 
	
	
		
			- 1.Power may differ depending upon the cold head used.
 
			- 2.Typical power consumption
 
			- 3.Cooling capacity may degrade if ambient temperature is above 28 °C (82 °F).
 
		
		Specifications subject to change without notice.
	
	Zephyr® Indoor Air-Cooled Compressor Series
	
		
		
			Specifications
			
				Specifications
				
					
				
				
					
						| Electrical Supply1 | 
						1 Phase 200 V, 220 V, 230/240 V, 50 Hz 220 V, 60 Hz | 
					
					
						| Power Consumption2 | 
						3.0 kW at 50 Hz 3.4 kW at 60 Hz | 
					
					
						| Ambient Temperature3 | 
						4-32 ºC (40-90 °F) | 
					
					
						| Cooling Air | 
						20 m3/min. (706 cfm), 50/60 Hz | 
					
					
						| Dimensions (HxWxD) | 
						715 x 453 x 488 mm (28.2 x 17.8 x 19.2 in.) | 
					
					
						| Weight | 
						102 kg (225 lbs.) 111 kg (245 lbs.) w/transformer | 
					
					
						| Maintenance | 
						30,000 Hours | 
					
				
			
		 
	
	
		
			- 1.Power may differ depending upon the cold head used.
 
			- 2.Typical power consumption
 
			- 3.Cooling capacity may degrade if ambient temperature is above 28 °C (82 °F).
 
		
		Specifications subject to change without notice.
	
	FA-40 Indoor Air-Cooled Compressor Series
	
		
		
			Specifications
			
				Specifications
				
					
				
				
					
						|   | 
						FA-40L | 
						FA-40H | 
					
					
						| Electrical Supply1 | 
						3 Phase 200 V, 50/60 Hz | 
						3 Phase 380-415 V, 50 Hz 460-480 V, 60 Hz | 
					
					
						| Power Consumption2 | 
						3.6-3.8 kW at 50 Hz 4.6-4.8 kW at 60 Hz | 
					
					
						| Ambient Temperature3 | 
						4-38 ºC (40-100 °F) | 
					
					
						| Cooling Air | 
						22 m3/min. (777 cfm), 60 Hz | 
					
					
						| Dimensions (HxWxD) | 
						889 x 442 x 493 mm (35.0 x 17.4 x 19.4 in.) | 
					
					
						| Weight | 
						110 kg (242 lbs.) | 
					
					
						| Maintenance | 
						30,000 Hours | 
					
				
			
		 
	
	
		
			- 1.Power may differ depending upon the cold head used.
 
			- 2.Typical power consumption
 
			- 3.Cooling capacity may degrade if ambient temperature is above 28 °C (82 °F).
 
		
		Specifications subject to change without notice.
	
	CSA-71A Indoor Air-Cooled Compressor Series
	
		
		
			Specifications
			
				Specifications
				
					
				
				
					
						| Electrical Supply1 | 
						3 Phase 200 V, 50/60 Hz | 
					
					
						| Power Consumption2 | 
						6.5-7.2 kW at 50 Hz 7.5-8.3 kW at 60 Hz | 
					
					
						| Ambient Temperature3 | 
						5-35 ºC (41-95 °F) | 
					
					
						| Cooling Air | 
						28 m3/min. (989 cfm), 50/60 Hz | 
					
					
						| Dimensions (HxWxD) | 
						885 x 550 x 550 mm (34.8 x 21.7 x 21.7 in.) | 
					
					
						| Weight | 
						140 kg (309 lbs.) | 
					
					
						| Maintenance | 
						20,000 Hours | 
					
				
			
		 
	
	
		
			- 1.Power may differ depending upon the cold head used.
 
			- 2.Typical power consumption
 
			- 3.Cooling capacity may degrade if ambient temperature is above 28 °C (82 °F).
 
		
		Specifications subject to change without notice.
	
	
	CNA-61 Indoor/Outdoor Air-Cooled Compressor Series
	
		
		
			Specifications
			
				Specifications
				
					
				
				
					
						|   | 
						CNA-61C | 
						CNA-61D | 
					
					
						| Electrical Supply1 | 
						3 Phase 200 V, 50/60 Hz | 
						3 Phase 380, 400, 415 V, 50 Hz 460, 480 V, 60 Hz | 
					
					
						| Power Consumption2 | 
						7.5-8.0 kW at 50 Hz 8.5-9.2 kW at 60 Hz | 
					
					
						| Ambient Temperature3 | 
						5-35 ºC (41-95 °F) - Indoor Unit -30-45 ºC (-22-133 °F) - Outdoor Unit | 
					
					
						| Cooling Air | 
						29.7 m3/min. (1049 cfm), 50 Hz 29.8 m3/min. (1052 cfm), 60 Hz | 
					
					
						| Dimensions (HxWxD) | 
						630 x 270 x 570 mm (24.8 x 10.6 x 22.4 in.) | 
						705 x 270 x 610 mm (27.8 x 10.6 x 24.0 in.) | 
					
					
						Weight (Indoor/Outdoor Units) | 
						45 kg (95 lbs.)/ 115 kg (254 lbs.) | 
						55 kg (121 lbs.)/ 115 kg (254 lbs.) | 
					
					
						| Maintenance | 
						20,000 Hours | 
					
				
			
		 
	
	
		
			- 1.Power may differ depending upon the cold head used.
 
			- 2.Typical power consumption
 
			- 3.Cooling capacity may degrade if ambient temperature is above 28 °C (82 °F).
 
		
		Specifications subject to change without notice.
	
	FA-70 Indoor/Outdoor Air-Cooled Compressor Series
	
		
		
			Specifications
			
				Specifications
				
					
				
				
					
						|   | 
						FA-70L | 
						FA-70H | 
					
					
						| Electrical Supply1 | 
						3 Phase 200 V, 50/60 Hz | 
						3 Phase 380/400/415 V, 50 Hz 460-480 V, 60 Hz | 
					
					
						| Power Consumption2 | 
						6.9-7.2 kW at 50 Hz 7.9-8.2 kW at 60 Hz | 
					
					
						| Ambient Temperature3 | 
						4-40 ºC (39-104 °F) - Indoor -30-45 ºC (-22-113 °F) - Outdoor | 
					
					
						| Cooling Air | 
						22 m3/min. (777 cfm), 60 Hz | 
					
					
						| Dimensions (HxWxD) | 
						547 x 262 x 637 mm (21.5 x 10.3 x 25.1 in.) - Indoor 948 x 1016 x 391 mm (37.3 x 40.0 x 15.4 in.) - Outdoor | 
					
					
						Weight (Indoor/Outdoor Units) | 
						46 kg (101 lbs.)/ 142 kg (313 lbs.) | 
					
					
						| Maintenance | 
						30,000 Hours | 
					
				
			
		 
	
	
		
			- 1.Power may differ depending upon the cold head used.
 
			- 2.Typical power consumption
 
			- 3.Cooling capacity may degrade if ambient temperature is above 28 °C (82 °F).
 
		